Technical Information

RSSI Radon Certifications:

National Environmental Health Association - National Radon Proficiency Program (#101198ARL, current through 11/30/09)

National Radon Safety Board (#ARL0014, current through 11/30/09)

Alpha-track Device Specifications:
Model number: AT-101
Internal chamber volume = 175 cc
Track reading area = 124 mm2
Maximum track count = 17,000
Lower limit of detection = 10 pCi-Days/L; 0.3 pCi/L for 30-day test; 0.1 pCi/L for 90-day test

Test duration: minimum = 14 days; maximum = 1 year or longer in normal situations

Quality Control Results:
National Proficiency Testing (Bowser-Morner, 8/20/07)
Average Relative Error = 0.038

Internal Quality Control Testing (RSSI, 2007)
Duplicates mean variance = 0.06
Repeat analysis mean variance = 0.006